SIGNAL
SOUNDWORKS

Sound & space / the thinking behind the work

The room is part
of the experience.

A conversation, a familiar record, a quiet scene in a film. What we hear comes from the source and from the space around it.

Hörsamkeit

German · suitability of a room for its intended sound activities

DIN 18041 uses this term for a room’s acoustic suitability, especially for speech communication and musical performance. Room shape, background noise, absorption, reflections, and reverberation all matter.

The standard provides guidance according to room use and dimensions. Hörsamkeit is a quality, not a unit of measurement or a universal comfort threshold. [1]

Sound, experienced
in context.

ISO’s soundscape framework considers how people perceive and experience an acoustic environment in context. The same sound can be experienced differently depending on the place, the activity, and the listener. [2]

Euphony is an older word for pleasing sound. We use it as a design aspiration. It is not a translation of Hörsamkeit or a numerical acoustic rating. [3]

Our design proposition is that the way a room sounds contributes to how it feels to spend time there. Absorption is one concrete part of that picture.

A worked example / 500 Hz

What could one large piece change?

A 12 × 14-foot dining room, an eight-foot ceiling, an 8 × 10-foot rug, a table, six hard chairs, and a sideboard. Add one 90 × 45-inch piece with a two-inch 703 core.

The furniture stays in place in both cases. Each seated person adds an assumed net 4.5 ft² sabins beyond the empty chair allowance.

Estimated starting absorption: ft² sabins.
Estimated net addition: 30.7 ft² sabins.

Before the artwork
0.80 s
With the artwork
0.58 s

27% shorter calculated reverberation time at 500 Hz.

An illustrative estimate based on material data and the assumptions below. This is not a measured room result or a percentage improvement in comfort. It does not establish compliance with DIN or Dolby guidance.

Read the assumptions and calculation

Sabine approximation: T₆₀ = 0.049 × V / A, with V in cubic feet and A in square-foot sabins. V = 1,344 ft³. This simplified enclosed-room model assumes a sufficiently diffuse sound field and omits doorway coupling and detailed window geometry. Actual small-room behavior depends on frequency and position.

ElementArea / allowanceCoefficient at 500 Hz
Drywall walls and ceiling584 ft²0.05
Uncovered wood floor88 ft²0.10
Rug, using carpet proxy data80 ft²0.14 or 0.57
Table, chairs, sideboard6 ft² sabins totalAssumed allowance
People4.5 ft² sabins net / personAssumed within published seating estimates
Plain 2-inch Owens Corning 70328.125 ft²1.14

Net panel addition = 28.125 × (1.14 − 0.05) = 30.66 ft² sabins, subtracting the wall area covered. The laboratory equivalent-area coefficient can exceed 1 due to test and edge effects; it is not a claim of absorbing more than all incident energy. The core’s coefficient is used as a proxy for the artwork; covering, framing, and mounting may change performance. [4] [5] [6] [7]

We do not assign a universal “ideal” such as 0.64 seconds. A target needs to match the room use, frequency bands, and assessment conditions. The calculation estimates reverberation, not speech intelligibility, perceived pleasure, or a guaranteed listening outcome.

Conversation.
Recorded sound.

At the table

Research on eating establishments connects absorption, occupancy, background noise, and the vocal effort needed for communication. It supports the mechanism; a busy restaurant study is not a direct test of this six-person home dining room. [8]

During a film

Dolby recommends absorptive and diffusive room treatment to manage unwanted reflections in its home-theater installation guidance. A listening-room design also depends on speakers, seating, early reflections, and low-frequency behavior. A single mid-frequency decay estimate cannot describe all of those factors. [9]

A more direct measure of speech

The Speech Transmission Index is an established method for rating speech intelligibility. It is a different metric from reverberation time, and we have not calculated or measured an STI value for this artwork. [10]

Follow the evidence

Sources & context.

  1. [1] DIN 18041:2016-03

    Acoustic quality in rooms: specifications and instructions for room acoustic design.

  2. [2] ISO 12913-1:2014 — Soundscape

    The definition and conceptual framework for understanding an acoustic environment as experienced in context.

  3. [3] Euphony — etymology

    The word’s history and its connection to pleasing sound.

  4. [4] Owens Corning 700 Series product data

    Plain, two-inch 703: laboratory absorption coefficient 1.14 at 500 Hz; Type A mounting. These data describe the core material.

  5. [5] OSHA Technical Manual — Noise

    Published absorption coefficients for drywall, wood flooring, and carpet constructions used as model proxies.

  6. [6] Published seating absorption table

    Historical estimates vary with seating and spacing. The model uses a rounded net-person allowance rather than claiming a fixed value for every diner.

  7. [7] CEDIA/CTA-RP22 — Immersive Audio Design

    Room-acoustic design practice, including the Sabine approximation and the role of direct and reflected sound.

  8. [8] Jens Holger Rindel — Verbal communication and noise in eating establishments (2010)

    A model of absorption, occupancy, and voice-level feedback in eating establishments.

  9. [9] Dolby Atmos Home Theater Installation Guidelines

    Guidance on sound-absorbing and sound-diffusing treatments for unwanted room reflections.

  10. [10] IEC 60268-16:2020 — Speech Transmission Index

    An objective method for rating speech intelligibility. No Dolby, DIN, or IEC endorsement or certification is claimed.